Yarway valves, desuperheaters and pump protection solutions have a strong reputation across various industries. Recognized by users all over the world as high quality products, the current Yarway valves and controls portfolio features advanced technologies that facilitate heavy-duty performance and excellent reliability. Contact Us View Products.

YARWAY COLOR-PORT WATER LEVEL GAUGES

YARWAY COLOR-PORT® WATER LEVEL GAUGES PG-60.1 WATER LEVEL INDICATORS Color-Port gauges provide continuous indication of boiler water levels as required by the ASME* Boiler and Pressure Code. Under PG-60, the Code states: PG-60.1: all boilers having a fixed water level (steam and water interface) shall have at least one

YarwaY water column InstallatIon, operatIon and …

1800 psig (124 barg) and 3000 psig (206.9 barg) design. the fittings on steam generators of lower pressure usually have a lesser rating. as a result, the overall rating of a system is governed by the lowest rating of any of the components. Steam connection piping shall be level or slope downward Steam drum Drum tapping centers column centers

YARWAY PROCESS THERMOSTATIC STEAM TRAPS …

3000 2000 1000 500 400 300 200 100 YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5 Condensate Capacity Near Steam Temperature (for steam trap sizing) The Series 151 Dual Range Steam Trap is designed for use on both batch and continuous applications such as batch stills, autoclaves, reboilers, storage tanks, shell and

YARWAY WATER COLUMNS, PROBES AND PROBE …

HP water column: 3000 psig (207 barg ) at saturation IP water column: 1800 psig (124 barg) at saturation LP water column: 850 psig (58 barg) at saturation Probes Max. pressures HP probe: 3000 psig (207 barg ) at saturation LP probe: 850 psig (58 barg) at saturation Max. temperatures HP probe: 1000°F (538°C) LP probe: 525°F (274°C) Fittings

Color-Port Water Level Gages

1800 to 3000 psi [124 to 207 bar] have visibility range of 12" to 48" [305 mm to 1219 mm]. How to Order Color-Port Gages For proper Color-Port Gage assembly, pressure,visibility, and gage connections consult selection chart, and visibility chart, pages 5 and 6. Use the order form at the end of the bulletin to order a complete Yarway Color ...

Water level indicator Yarway 3000

Description. An advanced, multi-featured five probe and above electronic alarm system for sensing water level in a variety of high or low pressure applications Features -Upgraded internal diagnostics for monitor clock, …

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS …

Learn about the features and benefits of Yarway Process Thermodynamic Steam Traps, a reliable and cost-effective solution for steam system applications. This data sheet provides technical specifications, installation and maintenance instructions, and ordering information for the series 129Y, 129YF, and 129Y-III models.

(PDF) YARWAY FLOAT TRAPS SERIES 23000, 26000, 33000€¦ …

TECHNICAL DATA Size: DN 15 - 25, 40, 50, 80 (NPS ½ - 1, 1½, 2, 3) Temperature: Up to 400°C (752°F) Connection: Socket weld (ASME, JIS) Flanged (ASME, JIS, JPI) Screwed (ISO 7-1) Pressure: Up to 4.6MPa (667psi) Materials: Carbon steel Stainless steel Series 23000 and 26000 for steam-using equipment, supporting high-volume drain discharge. …

YARWAY HANCOCK GLOBE VALVES MODEL 5525 AND …

3000 2000 1000 500 300 200 100 50 30 20 15 10 1000 800 600 500 400 300 200 150 100 80 60 50 40 30 20 15 1.0 0.8 0.6 0.4 0.2 0 50 60 70 80 90 100 YARWAY HANCOCK GLOBE VALVES MODEL 5525 AND 5535 Example 1: To determine the maximum flow rate of a NPS 1 figure 5525, 4 V-Port flow control valve flowing 70°F air to atmosphere at 100 …

Narvik-Yarway covers requirements for desuperheaters, …

The Narvik-Yarway pneumatic actuators are specifically developed for the Narvik-Yarway manufactured desuperheaters for use on low-, medium- and high pressure applications. The actuator models: 20-55 for a stroke of 55 mm and 20-90 for a stroke of 90 mm are suitable for operation under severe environmental conditions, e.g. at low or high ...

Yarway Series 2000

(3000 psig @ saturation, up to 1000°F [207 barg @ saturation, up to 538°C]) or threaded stainless steel LP electrode with PTFE (Teflon®) insulator (850 psig @ 525°F [58 barg @ 274°C]). The Series 2000 was developed for basic detection, display and switching. The Series 2000 consists of three major components: the column with probes,

Yarway Series 3000 Electronic Level Indication

Features. Upgraded internal diagnostics for monitor clock, power supply and level faults. Based on widely accepted conductivity probe technology. Reliable and cost-effective. Probes can be mounted directly to the pressure vessel or column. Independent detection circuit for each probe allows relay output selection for alarms or trips.

Aquarian Level Probe & Column

Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU.

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS …

3000 3500 4000 4500 5000 5500 6000 20 30 40 50 60 70 100 200 300 250/260 260 10 YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES C-250 AND C-260 HIGH PRESSURE TRAPS (VARIABLE ORIFICE) CONDENSATE CAPACITY NEAR STEAM TEMPERATURE (FOR STEAM TRAP SIZING) The Yarway high pressure …

Emerson YARWAY B Installation, Operation And Maintenance

Control Unit Emerson Yarway Color-Port 4511N Installation, Operation And Maintenance Instructions. Water level gauges & gauge valves (8 pages) Control Unit Emerson YARWAY 60Y Series Installation, Operation And Maintenance Manual. Impulse steam traps (6 pages) Control Unit Emerson CSI 6500 Quick Start Manual.

Válvula de Globo Welbond® Modelo 5600 para altas …

YARWAY Válvula de Globo Welbond® Modelo 5600 para altas presiones Instrucciones de instalación y mantenimiento Emerson se reserva el derecho a cambiar el contenido sin previo aviso página 2 Lubricación No es necesario lubricar el vástago, gracias a las propiedades antiagarrotamiento del casquillo de

YARWAY ARC PUMP PROTECTION VALVES …

Learn more about the features and benefits of Yarway ARC Pump Protection Valves, which are designed to prevent pump overheating and damage during low-load conditions. This data sheet provides detailed specifications, dimensions and installation instructions for the automatic recirculation valves.

YARWAY 3200 ELECTRONIC WATER LEVEL GAUGE …

• Stainless steel column 3000 psig (207 bar) 750°F (399°C) • 4 to 20 mA analog output module with RS485 serial output • FM approved systems • 16, 20, 24 (and up) probe systems 3.1 Analog 4 to 20 mA with RS485 Feature The Yarway 3200 Analog 4 to 20 mA Module is an intelligent I/O card. It is designed primarily

Yarway Corp. Asbestos Settlement Trust

Yarway Corp. The Yarway Asbestos Personal Injury Trust was created in 2015 with $326 million to pay injured victims. In 2018, trustees approved nearly 500 sites nationwide where Yarway asbestos-containing products were used. The trust pays claimants 25% of settlement amounts.

YarwaY SerieS 1001 elecTronic level indicaTion

YarwaY SerieS 1001 elecTronic level indicaTion SpECiFiCaTioNS SYSTEm CompoNENTS Steam line Probe dv alarm or trip drain line Probe fitting ... nPS 1½ (40 mm) tee (anSi class 3000 for lP probe, class 6000 or 9000 for HP probe). • 120/240 vac to 24 vac transformer and electronics in Type 4X/iP66 enclosure.

Yarway

1800 to 3000 psi [124 to 207 bar] have visibility range of 12" to 48" [305 mm to 1219 mm]. How to Order Color-Port Gages For proper Color-Port Gage assembly, pressure,visibility, and gage connections consult selection chart, and visibility chart, pages 5 and 6. Use the order form at the end of the bulletin to order a complete Yarway Color ...

YARWAY THROTTLING VALVES HY-DROP MODEL …

Rate of flow, pressure drop, or valve size can be determined by using the Yarway valve flow coefficient, Cv, in the following formulas: LIQUID Q = U.S. gpm W = lb/hr (Flowing conditions) GAS Q = Volumetric flow (SCFH) Kv = metric flow coefficient = (1 m³/hr water with 1 bar pressure drop) Kv = 0.865 Cv = Convert data to Imperial units and use

Steamtraps & Strainers | Askalon®

Steamtraps & Strainers. Yarway™ steam traps are suitable for a wide range of applications, with in-line repairable options. Steam traps are essential elements that remove condensate and air, thereby optimizing steam distribution and reducing energy costs. Yarway steam traps have a strong reputation for reliable operation and are suitable for ...

Bulletin for Yarway Model 25 VenTemp Desuperheater

from Yarway upon request. The actuation loop consists of a temperature sensor (1), transmitter (2), controller (3) and control valve with positioner (4) also electric systems are compatible and combinations of the two. Applications Yarway Ven-Temp Desuperheaters are used for temperature control of: • Process steam • Process gases

YARWAY FXT300 SERIES VARIABLE ORIFICE STEAM …

yarway fxt300 series variable orifice steam trap leverless float mechanical steam trap table 2. maximum capacity - lbs/hr 10°f below saturation type orifice, in. max. Δp, ... 0.261 250 670 1400 1900 2400 2540 3000 3500 4100 4200 4900 5100 5300 5500 5750 6000 fxt303 1.102 20 8000 15000 18000 19900 22800

Yarway

Yarway 1-1/2 in. Alloy Steel Socket Weld Globe Valve. Quick View Mfr. Part #5627B-SW-F22-1-1/2 4 out of 5 Customer Rating. $1.00 EACH Log in or Create Account. No Availability. Pick Up: Not available No Availability. Shipping: Not available Compare. Quick View Yarway Series 761 ...

Yarway | Emerson NL

Yarway valves, desuperheaters and pump protection solutions have a strong reputation across various industries. Recognized by users all over the world as high quality products, the current Yarway valves and controls portfolio features advanced technologies that facilitate heavy-duty performance and excellent reliability. Contact Us View Products.